This study revealed that there was a high correlation between the voxel values of CBCT and the CT numbers of MSCT. Although this was an in vitro study with assumed ideal conditions for measuring voxel values, there was a clear possibility for estimating CT numbers and BMD using the voxel values from the CBCT images, but the relationship was not entirely linear and should be examined further.
The potential advantage of magnetic resonance imaging (MRI) has been limited by artifacts due to the presence of metallic materials. For quantitative evaluation of the magnitude of artifacts from dental casting alloys and implant materials in MR imaging, 11 dental casting or implant materials were imaged by means of 1.5 T MRI apparatus with three different sequences. Mean and standard deviation of water signal intensity (SI) around the sample in the region of interest (1200 mm(2)) were determined, and the coefficient of variation was compared for evaluation of the homogeneity of the SI. A variety of artifacts with different magnitudes was observed. Only one of the samples, composed mainly of Pd, In, and Sb, showed no artifacts in all imaging sequences. We concluded that selection of specific dental casting alloys according to their elemental compositions could minimize the metal artifacts in MRI; however, titanium alloys currently pose a problem with respect to causing MRI artifacts.
This study was carried out to test the hypothesis that changes in head/body position induce changes in upper-airway dimensions. Contiguous images were obtained by means of magnetic resonance imaging in normal awake subjects during nasal breathing. A statistical analysis was made on 5 consecutive slices, including the most constricted sites in both the retropalatal and retroglossal regions. Dimensional changes in the upper airway in association with changes in head/body position were evaluated. In the retropalatal region, there was a significant decrease in the lateral dimension in the lateral recumbent position compared with that in the supine position. The cross-sectional area in the retroglossal region was significantly increased in both the "supine with the head rotated" and "lateral recumbent" positions. This change was accompanied by significant volumetric changes in the retroglossal region. Thus, sleeping with the head rotated may be effective for improving upper-airway obstruction.
Objectives: The aim was to investigate the possibility of evaluating the modulation transfer function (MTF) of cone beam CT (CBCT) for dental use using the oversampling method. Methods: The CBCT apparatus (3D Accuitomo) with an image intensifier was used with a 100 mm tungsten wire placed inside the scanner at a slight angle to the plane perpendicular to the plane of interest and scanned. 200 contiguous reconstructed images were used to obtain the oversampling line-spread function (LSF). The MTF curve was obtained by computing the Fourier transformation from the oversampled LSF. Line pair tests were also performed using CatphanH. Results: The oversampling method provided smooth and reproducible MTF curves. The MTF curves revealed that the spatial resolution in the z-axis direction was significantly higher than that in the axial direction. This result was also confirmed by the line pair test. Conclusions: MTF analysis was performed successfully using the oversampling method. In addition, this study clarified that the 3D Accuitomo had high spatial resolution, especially in the z-axis direction.
There was a linear correlation between the voxel values of CBCT and the contents of HA rod samples. Our study indicated that it might be possible to evaluate bone mineral content(BMC) from the voxel values of CBCT for dental implant treatment.
The static stabilometry patterns associated with Parkinson's disease (PD, n = 15) and spinocerebellar ataxia (SCA, n = 15) were compared with those of normal control (n = 15) by measuring the fractal dimensions. Fractal dimensions were estimated using the modified pixel dilation (mPD) method. The fractal dimensions with closed eyes showed a significant correlation with Environmental area for SCA group (p < 0.05). The fractal dimension for SCA group was significantly higher with closed eyes than that with open eyes (p < 0.05). The fractal dimension with closed eyes was significantly higher in PD and SCA groups than that in normal group (p < 0.05). The fractal dimension with closed eyes was higher when the clinical stage was more severe with PD and SCA group while Environmental and Longitude/Environmental areas were not. These findings suggest that the fractal dimension is more sensitive than traditional stabilometric analysis in an evaluation of postural instability in PD and SCA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.