Studies of rodent models of Alzheimer’s disease (AD) and of human tissues suggest that the retinal changes that occur in AD, including the accumulation of amyloid beta (Aβ), may serve as surrogate markers of brain Aβ levels. As Aβ has a wavelength-dependent effect on light scatter, we investigate the potential for in vivo retinal hyperspectral imaging to serve as a biomarker of brain Aβ. Significant differences in the retinal reflectance spectra are found between individuals with high Aβ burden on brain PET imaging and mild cognitive impairment (n = 15), and age-matched PET-negative controls (n = 20). Retinal imaging scores are correlated with brain Aβ loads. The findings are validated in an independent cohort, using a second hyperspectral camera. A similar spectral difference is found between control and 5xFAD transgenic mice that accumulate Aβ in the brain and retina. These findings indicate that retinal hyperspectral imaging may predict brain Aβ load.
Artificial intelligence technology has advanced rapidly in recent years and has the potential to improve healthcare outcomes. However, technology uptake will be largely driven by clinicians, and there is a paucity of data regarding the attitude that clinicians have to this new technology. In June–August 2019 we conducted an online survey of fellows and trainees of three specialty colleges (ophthalmology, radiology/radiation oncology, dermatology) in Australia and New Zealand on artificial intelligence. There were 632 complete responses (n = 305, 230, and 97, respectively), equating to a response rate of 20.4%, 5.1%, and 13.2% for the above colleges, respectively. The majority (n = 449, 71.0%) believed artificial intelligence would improve their field of medicine, and that medical workforce needs would be impacted by the technology within the next decade (n = 542, 85.8%). Improved disease screening and streamlining of monotonous tasks were identified as key benefits of artificial intelligence. The divestment of healthcare to technology companies and medical liability implications were the greatest concerns. Education was identified as a priority to prepare clinicians for the implementation of artificial intelligence in healthcare. This survey highlights parallels between the perceptions of different clinician groups in Australia and New Zealand about artificial intelligence in medicine. Artificial intelligence was recognized as valuable technology that will have wide-ranging impacts on healthcare.
Importance: Retinal ganglion cells endure significant metabolic stress in glaucoma but maintain capacity to recover function. Nicotinamide, a precursor of NAD + , is low in serum of glaucoma patients and its supplementation provides robust protection of retinal ganglion cells in preclinical models. However, the potential of nicotinamide in human glaucoma is unknown. Background: To examine the effects of nicotinamide on inner retinal function in glaucoma, in participants receiving concurrent glaucoma therapy. Design: Crossover, double-masked, randomized clinical trial. Participants recruited from two tertiary care centres. Participants: Fifty-seven participants, diagnosed and treated for glaucoma. Methods: Participants received oral placebo or nicotinamide and reviewed six-weekly. Participants commenced 6 weeks of 1.5 g/day then 6 weeks of 3.0 g/day followed by crossover without washout. Visual function measured using electroretinography and perimetry. Main outcome measures: Change in inner retinal function, determined by photopic negative response (PhNR) parameters: saturated PhNR amplitude (Vmax), ratio of PhNR/b-wave amplitude (Vmax ratio).
a b s t r a c tThis article presents a method for crop row structure characterization that is adapted to phenotypingrelated issues. In the proposed method, a crop row 3D model is built and serves as a basis for retrieving plant structural parameters. This model is computed using Structure from Motion with RGB images acquired by translating a single camera along the row. Then, to estimate plant height and leaf area, plant and background are discriminated by a robust method that uses both color and height information in order to handle low-contrasted regions. The 3D model is scaled and the plant surface is finally approximated using a triangular mesh.The efficacy of our method was assessed with two data sets collected under outdoor conditions. We also evaluated its robustness against various plant structures, sensors, acquisition techniques and lighting conditions. The crop row 3D models were accurate and led to satisfactory height estimation results, since both the average error and reference measurement error were similar. Strong correlations and low errors were also obtained for leaf area estimation. Thanks to its ease of use, estimation accuracy and robustness under outdoor conditions, our method provides an operational tool for phenotyping applications.
Interest in reliable biomarkers of Alzheimer disease, the leading cause of dementia, has been fuelled by challenges in diagnosing the disease and monitoring disease progression as well as the response to therapy. A range of ocular manifestations of Alzheimer disease, including retinal and lens amyloid-beta accumulation, retinal nerve fiber layer loss, and retinal vascular changes, have been proposed as potential biomarkers of the disease. Herein, we examine the evidence regarding the potential value of these ocular biomarkers of Alzheimer disease.
PurposeTo compare the RETeval sensor strip and Dawson-Trick-Litzkow (DTL) electrodes for recording the photopic negative response (PhNR) using a portable electroretinogram (ERG) device in eyes with and without glaucoma.MethodsTwenty-six control and 31 glaucoma or glaucoma-suspect participants were recruited. Photopic ERGs were recorded with sensor strip and DTL electrodes in random order using the LKC RETeval device. Stimuli consisted of brief, red flashes (1.7 cd.s/m2) on a blue background (photopic 10 cd/m2). The PhNR amplitude was measured from baseline to trough and also expressed as a ratio over the b-wave amplitude.ResultsThe sensor strip-recorded PhNR amplitude was significantly attenuated (mean ± standard deviation [SD], 4.8 ± 2.1 vs. 12.7 ± 4.8 μV, P < 0.0001), with lower signal-to-noise ratio (SNR; 5.5 ± 2.1 vs. 8.1 ± 3.9, P < 0.0001), and a trend toward a larger PhNR/b-wave ratio compared with DTL electrodes. The PhNR amplitude, implicit time and PhNR/b-wave ratio correlated with visual field mean light sensitivity, although this fell short of significance for the sensor strip recorded PhNR amplitude. The electrodes demonstrated similar intersession repeatability with a coefficient of repeatability of ±27% and ±28% for the DTL and sensor strip, respectively.ConclusionsSensor strip electrodes are a viable alternative for recording reproducible PhNRs, especially when values are normalized to the b-wave. However, DTL electrodes should be considered in cases of attenuated PhNR, or in elevated noise levels, due to its better signal-to-noise quality.Translational RelevanceSensor strip electrodes can simplify PhNR recordings in the clinic, potentially eliminating the need for an experienced operator.
PurposeThe photopic negative response (PhNR) of the light-adapted electroretinogram (ERG) holds promise as an objective marker of retinal ganglion cell function. We compared baseline detrending methods to improve PhNR repeatability without compromising its diagnostic ability in glaucoma.MethodsPhotopic ERGs were recorded in 20 glaucoma and 18 age-matched control participants. A total of 50 brief, red-flashes (1.6 cd.s/m2) on a blue background (10 photopic cd/m2) were delivered using the RETeval device. Detrending methods compared were: (1) increasing the high-pass filter from 1 to 10 Hz and (2) estimating and removing the trend with an increasing polynomial (order from 1–10) applied to the prestimulus interval, prestimulus and postsignal interval, or the whole ERG signal. Coefficient of repeatability (COR%), unpaired Student's t-test, and area under the receiver operating characteristic curve (AUC) were used to compare the detrending methods.ResultsMost detrending methods improved PhNR test–retest repeatability compared to the International Society for Clinical Electrophysiology of Vision (ISCEV) recommended 0.3 to 300 Hz band-pass filter (COR% ± 200%). In particular, detrending with a polynomial (order 3) applied to the whole signal performed the best (COR% ± 44%) while achieving similar diagnostic ability as ISCEV band-pass (AUC 0.74 vs. 0.75, respectively). However, over-correcting with higher orders of processing can cause waveform distortion and reduce diagnostic ability.ConclusionsBaseline detrending can improve the PhNR repeatability without compromising its clinical use in glaucoma. Further studies exploring more complex processing methods are encouraged.Translational RelevanceBaseline detrending can significantly improve the quality of the PhNR.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.